The Aaronia Zero-Gauss-Chamber sets up a magnetic field-free environment to calibrate units and sensors in conditions which are free of static magnetic fields or earth magnetism.
It provides a zero gauss, magnetic field-free environment. This massive super heavy version offers a very high 10 times shielding against earth magnetic fields. Therefore measuring results may be reproduced at any geographical location, while quality on a global scale can be assured.
The wide inner chamber-diameter of 110mm enables the zero-gauss-calibration of very big parts or units like our SPECTRAN® devices with static magnetic-field-sensor.
Aaronia Zero-Gauss-Chamber
V6-RSA250X | V6-RSA500X |
V6-RSA2000X |
|
---|---|---|---|
Frequency Range (min) | 10 MHz | ||
Frequency Range (max) | 8 GHz (Basic version 6 GHz) | ||
Real-Time Bandwidth | 80 MHz/opt. 120 MHz | 80 MHz/opt. 120 MHz | 160 MHz/opt. 245 MHz* |
Sweep speed | 300/440 GHz/s | 300/440 GHz/s | 730/1100 GHz |
Signal Generator | - / opt. 120 MHz | 120 MHz | 120 MHz |
I/Os | 1 Rx (opt. 1 Tx) | 1 Rx & 1 Tx | 2 Rx & 1 Tx |
Technical specifications | Spectran V6 X |
---|---|
Real-time bandwidth Rx | Up to 245 MHz (I/Q - via 2 x USB)* |
Real-time bandwidth Tx | 120 MHz (opt. 245MHz) |
POI (FFT-based) | Up to 97 ns |
POI (I/Q-based) | Up to 10 ns |
Max. power Rx | +23 dBm |
Max. power Tx | +20 dBm |
DANL (internal pre-amp on) | Typ. -170 dBm/Hz |
Amplitude accuracy (typ.) | Typ. +/- 0,5 dB (compensated by FIR filter) |
USB streaming connection | One or two USB 3.0 (USB 3.1 Gen1; USB 3.2 Gen1) |
USB bandwidth | Up to 784 MBytes/s sustained throughput to PC (dual USB 3.0) |
Frequency reference accuracy | 0,5 ppm (5 ppb via OCXO option) With GPS Disciplined Time Base: 5 ppb (optional 200 ppt) |
RBW (resolution bandwidth) | 62 mHz to 200 MHz |
Measurement units | Over 20 (e.g. dBm, dBμV, V/m, A/m, W/m², dBμV/m, W/cm²) |
Detector | Min, Max, AVG, Peak, QPeak |
Attenuator range | 50 dB / 70 dB (0,5 dB steps) |
Traces | Over 20 (e.g. ACT, AVG, MAX, MIN, QPEAK) |
Measurement modes | True IQ or Power/Frequency data |
Trigger | Cursor, Measurement, Density |
ADC | Dual 2GSPS 16 Bit |
DAC | 2GSPS 14-Bit |
GPS | GPS/QZSS, GLONASS, BeiDou and Galileo (concurrent reception) |
GPS synchronisation | +/- 10ns timestamping in each data packet |
External Frequenc Reference Input | typ. 10MHz, 3,5VRMS into 50 Ohm (SMB-connector) |
FPGA | XC7A200T-2 |
DSP processing | 930 GMACs |
SDRAM | 2 GB |
RF connectors | SMA (Rx,Tx), SMB (Trigger, Refclock, GPS, PPM). All 50 Ohms. |
Temperature range (operation) | 0 °C to +50 °C (extended -40 to +75 °C) |
Dimensions | 210 x 115 x 30 mm |
Weight | 850 g |
Power | USB 3.2 Gen 1 Type-C PD 3.0 |
Power consumption | Typical 15 W |
Country of origin | Germany |
Recommended calibration interval | 2 years |